Data Foundry

CPSC recalls 2002

CPSC, BY US International Co. Announce Recall of "NEXT" Ultra Shock Bicycles Sold at Wal-Mart

U.S. Consumer Product Safety Commission recall (2002-06-20). Hazards: electric shock, fall, crash. Models: 8524-14, 8526-20. About 132,000 units in the US.

AgencyU.S. Consumer Product Safety Commission
Recall number02183
Published2002-06-20
Last updated2025-09-22
Product categoryBicycles & Accessories
ProductsNext Ultra Shock mountain bicycles with "Ballistic 105" front suspension forks
Firm named in the titleBY US International Co.
FirmsBY US International Co. Ltd., of Taiwan (manufacturer); Dynacraft Industries Inc., of San Rafael, Calif. (distributor)
Manufactured inTaiwan
Units (US)132,000
Model numbers8524-14, 8526-20
Hazard classeselectric shock, fall, crash
Remedy classesreplace, stop use
SoldWal-Mart stores nationwide sold these mountain bikes, from May 1999 through December 2000, for about $150.

Description

The recall includes only Next Ultra Shock bicycles, which are blue, with model numbers 8524-14 and 8526-20. They were manufactured between April 1999 and November 9, 1999. A label affixed to the frame near the crank housing identifies the model and date of manufacture. The name "Ultra Shock" is written on the bicycle down tube in white lettering. Next Ultra Shock bicycles manufactured after November 9, 1999, did not use BY US International-made Ballistic forks, and are not subject to this recall.

Hazard

The forks on these bicycles can break apart, causing riders to lose control, fall and suffer serious injury.

Remedy

Consumers should stop using these bicycles immediately and call Dynacraft Industries for information on receiving a free replacement fork and free installation.

Incidents and injuries

There have been 20 reports of the suspension forks breaking on the Next Ultra Shock bicycles, resulting in 19 riders suffering injuries that include abrasions, concussions and chipped teeth.