Data Foundry

CPSC recalls 2001

CPSC, Suzuki Motor Corporation Announce Recall of ATVs

U.S. Consumer Product Safety Commission recall (2001-11-15). About 4,000 units in the US.

AgencyU.S. Consumer Product Safety Commission
Recall number02507
Published2001-11-15
Last updated2025-10-17
Product categoryAll Terrain Vehicles (ATVs)
Products2002 Suzuki "Eiger" LT-F400K2 and LT-F400FK2 ATVs
Firm named in the titleSuzuki Motor Corporation
FirmsSuzuki Motor Corporation of Brea, Calif. (manufacturer)
Units (US)4,000
Remedy classesrepair, inspect
SoldSuzuki dealers nationwide sold these ATVs, from September through mid-October 2001, for between $4,199 and $4,999.

Description

The Suzuki "Eiger" LT-F400K2 and LT-F400FK2 (two and four-wheel drive) ATVs have manual transmissions. These models carry the identifications "Suzuki" and "Eiger" on both sides of the bodywork, inboard of the operator's knee location. The ATVs are available in both red and green.

Hazard

The nut that secures the LT-F400K2 and LT-F400FK2 clutch shoe will come loose during operation. When the nut loosens, the clutch shoe will become loose on the crankshaft. In some cases this will cause severe damage to the clutch wheel and crankshaft or can cause the crankshaft to break. This will interrupt power transfer from the engine to the transmission and the drive wheels and may leave the rider stranded away from his or her base of operation.

Remedy

Consumers should contact their local Suzuki dealer to schedule an appointment for their ATV to be inspected and repaired. The inspection and repair will be performed at no cost.

Incidents and injuries

None reported.