CPSC, Porter-Cable Announce Recall to Repair Circular Saws

U.S. Consumer Product Safety Commission recall (2005-11-29). Hazards: laceration. Models: 324MAG. About 196,000 units in the US.

AgencyU.S. Consumer Product Safety Commission
Recall number06040
Published2005-11-29
Last updated2024-04-16
Product categoryCircular Saws
ProductsPorter-Cable® 7¼-inch MAG-Saw™ Circular Saws
Firm named in the titlePorter-Cable
FirmsPorter-Cable, of Jackson, Tenn. (manufacturer)
Manufactured inUnited States
Units (US)196,000
Model numbers324MAG
Hazard classeslaceration
Remedy classesrepair, inspect, stop use
SoldMajor home center and hardware stores nationwide from March 2004 through November 2005 for between $130 and $160, depending on the model.

Description

The recall involves Porter-Cable® 7¼-inch MAG-Saw™ Circular Saws with model numbers 324MAG (serial numbers 10001 through 108962), 325MAG (serial numbers 10001 through 014712), 423MAG (serial numbers 10001 through 100371), and 424MAG (serial numbers 10001 through 012690). The model and serial numbers are located on a label on the top of the saws. Units marked with a "T" at the location shown below have been inspected and are not affected by this recall. "Porter-Cable®" is written on the side of these saws.

Hazard

The lower guard on these saws could stick in the open position, posing a risk of severe lacerations to consumers.

Remedy

Consumers should stop using the circular saws immediately and contact Porter-Cable for the location of the nearest service center to receive a free inspection and repair, if necessary.

Incidents and injuries

None reported.