CPSC, Porter-Cable Announce Recall to Repair Circular Saws
U.S. Consumer Product Safety Commission recall (2005-11-29). Hazards: laceration. Models: 324MAG. About 196,000 units in the US.
| Agency | U.S. Consumer Product Safety Commission |
|---|---|
| Recall number | 06040 |
| Published | 2005-11-29 |
| Last updated | 2024-04-16 |
| Product category | Circular Saws |
| Products | Porter-Cable® 7¼-inch MAG-Saw™ Circular Saws |
| Firm named in the title | Porter-Cable |
| Firms | Porter-Cable, of Jackson, Tenn. (manufacturer) |
| Manufactured in | United States |
| Units (US) | 196,000 |
| Model numbers | 324MAG |
| Hazard classes | laceration |
| Remedy classes | repair, inspect, stop use |
| Sold | Major home center and hardware stores nationwide from March 2004 through November 2005 for between $130 and $160, depending on the model. |
Description
The recall involves Porter-Cable® 7¼-inch MAG-Saw™ Circular Saws with model numbers 324MAG (serial numbers 10001 through 108962), 325MAG (serial numbers 10001 through 014712), 423MAG (serial numbers 10001 through 100371), and 424MAG (serial numbers 10001 through 012690). The model and serial numbers are located on a label on the top of the saws. Units marked with a "T" at the location shown below have been inspected and are not affected by this recall. "Porter-Cable®" is written on the side of these saws.
Hazard
The lower guard on these saws could stick in the open position, posing a risk of severe lacerations to consumers.
Remedy
Consumers should stop using the circular saws immediately and contact Porter-Cable for the location of the nearest service center to receive a free inspection and repair, if necessary.
Incidents and injuries
None reported.
Machine access
This record, with every extracted field, the source record (contact text and images withheld) and provenance: GET https://api.data.aroqon.com/v1/product-recalls/cpsc-06040. Look up a model number or UPC with /v1/product-recalls/lookup?code=…. About the dataset · free and paid keys.
Source: U.S. Consumer Product Safety Commission recall notice (US Government work). Not affiliated with or endorsed by CPSC. Structured by Data Foundry (product-recall-structuring@2); last changed 2026-09-28. Always confirm with the agency notice.