Data Foundry

CPSC recalls 2006

CPSC, Brunswick Bowling & Billiards Corp. Announce Recall of Frameworx Table Height Chairs and Bar Stools

U.S. Consumer Product Safety Commission recall (2006-08-11). Hazards: fall. Models: 53-861025-000, 57-860979-000. About 22,400 units in the US.

AgencyU.S. Consumer Product Safety Commission
Recall number06572
Published2006-08-11
Last updated2024-08-14
Product categoryChairs, Stools & Benches
ProductsFrameworx Table Height Chairs and Bar Stools
Firm named in the titleBrunswick Bowling & Billiards Corp.
FirmsBrunswick Bowling & Billiards Corp., of Lake Forest, Ill. (manufacturer)
Manufactured inUnited States
Units (US)22,400
Model numbers53-861025-000, 57-860979-000
Hazard classesfall
Remedy classesrepair, stop use
SoldDistributors of Brunswick Bowling furniture selling to bowling center operators. This product was not sold to the general public. The chairs were sold from September 1995 through May 2004.

Description

The recalled chairs and bar stools were sold under the model name Frameworx. The models affected are short table height chair model number 53-861025-000 and tall bar stool model number 57-860979-000. The model name and model numbers are not written on the chairs. The model number is only written on the original shipping carton, packing list or invoice. The chairs and bar stools have a plastic bucket-style seat bolted to a steel seat plate assembly that connects to the down tube of the seat.

Hazard

The down shaft on the seat plate assembly can fracture, which can cause an occupant of the seat to fall.

Remedy

Bowling centers owning these table height chairs and bar stools have been directly notified about this recall. Owners of the bar stools and table height chairs should stop using these products immediately and contact Brunswick to receive a free repair kit.

Incidents and injuries

Brunswick has received reports of 20 incidents in which the seat plate assembly has failed. Three injuries resulting from falling from a seat have been reported.

Machine access

This record, with every extracted field, the source record (contact text and images withheld) and provenance: GET https://api.data.aroqon.com/v1/product-recalls/cpsc-06572. Look up a model number or UPC with /v1/product-recalls/lookup?code=…. About the dataset · free and paid keys.

Source: U.S. Consumer Product Safety Commission recall notice (US Government work). Not affiliated with or endorsed by CPSC. Structured by Data Foundry (product-recall-structuring@2); last changed 2026-09-28. Always confirm with the agency notice.