Data Foundry

CPSC recalls 2007

One World Technologies Recalls Throat Plates Sold with Ryobi Router Tables Due to Laceration Hazard

U.S. Consumer Product Safety Commission recall (2007-03-06). Hazards: laceration. Models: RT101, R161RTA, R162RTA. About 100,000 units in the US.

AgencyU.S. Consumer Product Safety Commission
Recall number07120
Published2007-03-06
Last updated2014-05-23
Product categoryRouters & Accessories
ProductsRyobi Router Table Throat Plates
Firm named in the titleOne World Technologies
FirmsOne World Technologies Inc., of Anderson, S.C. (manufacturer)
Manufactured inChina
Units (US)100,000
Model numbersRT101, R161RTA, R162RTA
Hazard classeslaceration
Remedy classesreplace, stop use
SoldHome Depot stores nationwide between May 2004 and January 2007 for about $100 for the combo kits that include the router, router table and throat plates.

Description

The recall involves Ryobi-brand router tables, with model number RT101, which is written on the table's data plate, located on its front leg. These tables were sold as part of the Ryobi combo kits with model numbers R161RTA and R162RTA. The combo kit model number is written on the packaging. A router table holds the router underneath the table. Instead of moving the router over the wood, the table allows the user to guide the wood for cutting. The throat plates are components of the table that consist of five yellow plastic rings. They serve as a guide for the router bit and provide a stable surface around the bit.

Hazard

The throat plates do not securely snap into the router's table top bit opening. The throat plate can come loose during operation and be ejected from the table top, posing a laceration hazard to consumers.

Remedy

Consumers should immediately check their router tables to ensure that the throat plates securely snap into the router bit opening. If any throat plates do not securely snap into the table top, consumers should stop using the router table immediately and contact One Word Technologies for a free replacement set of throat plates.

Incidents and injuries

One World Technologies has received three reports of throat plates coming loose during use. Two consumers were struck on the nose by the throat plate and received a minor cut and bruising.

Machine access

This record, with every extracted field, the source record (contact text and images withheld) and provenance: GET https://api.data.aroqon.com/v1/product-recalls/cpsc-07120. Look up a model number or UPC with /v1/product-recalls/lookup?code=…. About the dataset · free and paid keys.

Source: U.S. Consumer Product Safety Commission recall notice (US Government work). Not affiliated with or endorsed by CPSC. Structured by Data Foundry (product-recall-structuring@2); last changed 2026-09-28. Always confirm with the agency notice.