Sony Recalls Notebook Computers Due to Burn Hazard

U.S. Consumer Product Safety Commission recall (2008-09-04). Hazards: burn. Models: VGN-TZ100, VGN-TZ200, VGN-TZ300, VGN-TZ2000. About 73,000 units in the US.

AgencyU.S. Consumer Product Safety Commission
Recall number08392
Published2008-09-04
Last updated2014-05-23
Product categoryComputer Equipment
ProductsCertain VAIO TZ-series Notebook Computers
Firm named in the titleSony
FirmsSony Electronics Inc., of San Diego, Calif. (manufacturer)
Manufactured inJapan, United States
Units (US)73,000
Model numbersVGN-TZ100, VGN-TZ200, VGN-TZ300, VGN-TZ2000
Hazard classesburn
Remedy classesrepair, inspect, stop use
SoldThe SonyStyle stores and Web site, authorized electronics retailers, and authorized business-to-business dealers nationwide from July 2007 through August 2008 for between $1,700 and $4,000.

Description

The recalled notebook computer models are the VAIO VGN-TZ100 series, VGN-TZ200 series, VGN-TZ300 series and VGN-TZ2000 series. The computers' screen size is about 11.1" measured diagonally. Not all units are affected; consumers should contact Sony to determine if their unit is included in the recall.

Hazard

Irregularly positioned wires near the computer's hinge and/or a dislodged screw inside the hinge can cause a short circuit and overheating. This poses a burn hazard to consumers.

Remedy

Consumers should stop using the recalled notebook computers immediately and contact Sony to determine if their notebook is affected. The firm will arrange for an inspection and repair, if needed.

Incidents and injuries

Sony has received 15 reports of overheating, including one consumer who suffered a minor burn.

Machine access