Data Foundry

CPSC recalls 2010

Coil Nailers Recalled by Hitachi Koki Due to Serious Injury Hazard

U.S. Consumer Product Safety Commission recall (2010-03-11). Hazards: injury. Models: NV83A2. About 50,000 units in the US and 15,000 in Canada.

AgencyU.S. Consumer Product Safety Commission
Recall number10163
Published2010-03-11
Last updated2014-05-23
Product categoryNailers
ProductsCoil Nailers
Firm named in the titleHitachi Koki
FirmsHitachi Koki Co. Ltd., of Japan (manufacturer); Hitachi Koki U.S.A., Ltd., of Norcross, Ga. (importer)
Manufactured inJapan
Units (US)50,000
Units (Canada)15,000
Model numbersNV83A2
Hazard classesinjury
Remedy classesrepair, stop use
SoldLowe's, Home Depot, other home improvement and building supply stores and online at Amazon.com nationwide from November 2002 through March 2006 for between $350 and $400.

Description

The coil nailers are used to project nails into drywall, wood or other materials. The model number is NV83A2 and can be found on the body of the product. Only those units manufactured between October 2002 and September 2005 are included in this recall. The manufacturing date can be identified by the serial number engraved at the end of the handle, the first digit representing the month (1 for January, 2 for February, 3 for March, 4 for April, 5 for May, 6 for June, 7 for July, 8 for August, 9 for September, O for October, N for November and D for December) and the second digit representing the year (2 for 2002, 3 for 2003, 4 for 2004 and 5 for 2005).

Hazard

The nailers could have a faulty feeder that can allow nails to be ejected sideways, posing a serious injury hazard to the user or bystanders.

Remedy

Consumers should immediately stop using the recalled coil nailer and contact Hitachi Koki U.S.A., Ltd. for a free repair.

Incidents and injuries

The firm has received 37 reports of nails being ejected sideways, including 15 reports of injuries. The injuries were primarily in the eye region, including five reports of partial blindness.

Machine access

This record, with every extracted field, the source record (contact text and images withheld) and provenance: GET https://api.data.aroqon.com/v1/product-recalls/cpsc-10163. Look up a model number or UPC with /v1/product-recalls/lookup?code=…. About the dataset · free and paid keys.

Source: U.S. Consumer Product Safety Commission recall notice (US Government work). Not affiliated with or endorsed by CPSC. Structured by Data Foundry (product-recall-structuring@2); last changed 2026-09-28. Always confirm with the agency notice.