Data Foundry

CPSC recalls 2011

Lasko Recalls Portable Electric Heaters Due To Fire Hazard

U.S. Consumer Product Safety Commission recall (2011-02-08). Hazards: fire, burn. Models: 5540, 8540. About 107,500 units in the US.

AgencyU.S. Consumer Product Safety Commission
Recall number11121
Published2011-02-08
Last updated2016-04-28
Product categoryPortable Electric Heaters
ProductsPortable electric heater
Firm named in the titleLasko
FirmsLasko Products Inc., of West Chester, Pa. (manufacturer)
Manufactured inChina
Units (US)107,500
Model numbers5540, 8540
Hazard classesfire, burn
Remedy classesreplace, stop use
Trade facetshvac
SoldThe Lasko Model 5540 was sold at Sam's Club and other retailers from September 2002 through early 2004 for $39 to $49. The Air King Model 8540 was sold primarily through the maintenance, repair and operating products supply company, W.W. Grainger Inc. from late 2002 to 2004 for approximately $80.00

Description

The portable electric tower heaters are 20.5 inches tall x 8.25 inches wide x 9.25 inches deep. They are dark grey with silver front covers and black vent slats. The brand names Lasko or Air King are on the top, center of the front cover. The Lasko Model 5540 and Air King Model 8540 subject to this recall were manufactured in 2002 and have date codes that begin with a "2." The date code is on the label located on the bottom of the unit. The date code is a four-digit number on the bottom left area of the label, above the voltage number. Heaters with date codes beginning with "3" "4" or "5" are not subject to this recall.

Hazard

An electrical connection in the base of the unit can overheat, causing it to melt and expose the electrical connection, posing a fire hazard to consumers.

Remedy

Consumers should stop using the heaters immediately and contact Lasko to receive a free replacement heater.

Incidents and injuries

Lasko received a total of 36 reports of the electrical connection overheating with no reports of injury. There were 18 reports of minor burn damage to floors or carpets