Data Foundry

Drug recalls 2024

VANCOmycin HCl PF 1 — Class I drug recall D-0281-2024

Ongoing recall by Denver Solutions, LLC DBA Leiters Health, reported 2024-02-07, distributed nationwide. Superpotent Drug: semi-automated IV bag filling system can malfunction and provide a double dose of drug produ

Recall numberD-0281-2024
Product typeDrug
ClassificationClass I
StatusOngoing
Voluntary or mandatedVoluntary
Recalling firmDenver Solutions, LLC DBA Leiters Health, Englewood, CO, United States
Recall initiated2023-12-28
Classified2024-01-29
Reported by FDA2024-02-07
DistributedNationwide (US)
Quantity10,152 iv
Reason classespotency, device malfunction
NDC71449-0028-68
Lot numbers2331184, 2331185, 2331189, 2331191, 2331258, 2331317
Model numbersF3206
Expiration dates2024-02-10, 2024-02-13, 2024-02-20, 2024-02-24, 2024-03-03, 2024-03-15

Product

VANCOmycin HCl PF 1.25g added to 0.9% Sodium Chloride 250 mL IV bag, Item F3206, for IV use only; Leiters 13796 Compark Blvd Englewood, CO 80112; NDC 71449-028-68.

Reason for recall

Superpotent Drug: semi-automated IV bag filling system can malfunction and provide a double dose of drug product to IV bags.