METHIONINE/INOSITOL/CHOLINE CHLORIDE/CHROM/B12 — Class II drug recall D-1572-2012
Terminated recall by Franck's Lab Inc., d.b.a. Franck's Compounding Lab, reported 2012-08-22, distributed nationwide. Lack of Assurance of Sterility: Franck's Lab Inc. initiated a recall of all Sterile Human Drugs distributed be
| Recall number | D-1572-2012 |
|---|---|
| Product type | Drug |
| Classification | Class II |
| Status | Terminated |
| Voluntary or mandated | Voluntary |
| Recalling firm | Franck's Lab Inc., d.b.a. Franck's Compounding Lab, Ocala, FL, United States |
| Recall initiated | 2012-05-21 |
| Classified | 2012-08-10 |
| Reported by FDA | 2012-08-22 |
| Terminated | 2014-08-15 |
| Distributed | Nationwide (US) |
| Countries outside the US | BS, DO, GT, KY, PL, VE |
| Quantity | 78 units |
| Reason classes | microbial contamination, sterility |
| Pathogens | mold |
Product
METHIONINE/INOSITOL/CHOLINE CHLORIDE/CHROM/B12 (C) 0.8/1.6/1.6/0.0001/0.03% INJE 10 ML 200 ML 30 ML 50 ML; METHIONINE/INOSITOL/CHOLINE CHLORIDE/CHROM/B12 (M) 0.8/1.6/1.6/0.0001/0.03% INJE 10 ML 150 ML 180 ML 30 ML 360 ML 4 ML 5 ML; METHIONINE/INOSITOL/CHOLINE CHLORIDE/CHROM/VIT B-12 0.8/1.6/1.6/0.0001/0.03% IN 30 ML; METHIONINE/INOSITOL/CHOLINE CHLORIDE/CHROMIUM CHLORIDE 0.8/1.6/1.6/0.0001/0.03% 100 ML 30 ML 80 ML; METHIONINE/INOSITOL/CHOLINE CHLORIDE/VIT B12 0.8%/1.6%/1.6%/1200MCG/ML INJECTABL 30 ML; METHIONINE/INOSITOL/CHOLINE CL/B6/B12/CHROM/ (C) 25/50/50/100/1MG/4MCG 5 ML; METHIONINE/INOSITOL/CHOLINE/CHROMIUM W/O B-12 0.8/1.6/1.6/0.0001% INJECTABLE 30 ML (18 DIFFERENT PRODUCTS)
Reason for recall
Lack of Assurance of Sterility: Franck's Lab Inc. initiated a recall of all Sterile Human Drugs distributed between 11/21/2011 and 05/21/2012. FDA environmental sampling revealed the presence of microorganisms and fungal growth in the clean room where sterile products were prepared.