Visual-ICE Cryoablation System — Class II medical device recall Z-0404-2020

Terminated recall by Galil Medical, Inc., reported 2019-11-20, distributed in AK, AL, AR, AZ, CA, FL, GA, HI…. Visual-ICE utilizing the IceSeed 1.5 and IceRod 1.5 PLUS cryoablation needles could have issues with the needl

Recall numberZ-0404-2020
Product typeMedical device
ClassificationClass II
StatusTerminated
Voluntary or mandatedVoluntary
Recalling firmGalil Medical, Inc., Saint Paul, MN, United States
Recall initiated2019-10-25
Classified2019-11-14
Reported by FDA2019-11-20
Terminated2020-09-16
DistributedAK, AL, AR, AZ, CA, FL, GA, HI, KY, MA, MI, MN, NC, ND, NY, OH, PA, PR, SC, TN, UT, VA
Countries outside the USAR, CA, GB, TW
Quantity49 systems
Serial numbersPM0486M, PM0488M, PM0489M, PM0490M, PM0491M, PM0492M, PM0497M, PM0498M, PM0499M, PM0500M, PM0506M, PM0507M, PM0512M, PM0513M, PM0514M, PM0515M, PM0516M, PM0520M, PM0523M, PM0524M, PM0525M, PM0526M, PM0527M, PM0528M, PM0529M and 73 more

Product

Visual-ICE Cryoablation System, FPRCH6000. The cryoablation system is a mobile console system intended for cryoablative tissue destruction using a minimally invasive procedure. The system is computer-controlled with a touch screen user interface that allows the user to control and monitor the procedure. The therapy delivered by the system is based on the Joule-Thomson effect displayed by compressed gases. The Visual-ICE System uses high-pressure argon gas that circulates through closed-tip cryoablation needles to induce tissue freezing. Active tissue thawing is achieved by circulating helium gas through the needles or, alternatively , by the use of Galil Medical I-Thaw technology in which a heating element inside the cryoablation needle can be energized to cause thawing.

Reason for recall

Visual-ICE utilizing the IceSeed 1.5 and IceRod 1.5 PLUS cryoablation needles could have issues with the needle clogging and/or inadequate freezing performance.