AIA-2000 Analyzer — Class II medical device recall Z-0475-2019
Terminated recall by Tosoh Bioscience Inc, reported 2018-11-28, distributed nationwide. There is a possibility that the liquid suction pump on some AIA-2000 analyzers may not perform as intended and
| Recall number | Z-0475-2019 |
|---|---|
| Product type | Medical device |
| Classification | Class II |
| Status | Terminated |
| Voluntary or mandated | Voluntary |
| Recalling firm | Tosoh Bioscience Inc, Grove City, OH, United States |
| Recall initiated | 2018-09-28 |
| Classified | 2018-11-16 |
| Reported by FDA | 2018-11-28 |
| Terminated | 2020-05-29 |
| Distributed | Nationwide (US) |
| Quantity | 7 |
| Serial numbers | 10038409, 10038509, 10048009R, 10058011, 10069507, 80018112, 80039511 |
| Model numbers | AIA-2000LA, AIA-2000ST |
Product
AIA-2000 Analyzer, Model Nos. AIA-2000LA, AIA-2000ST - Product Usage: The AIA-2000 is capable of performing three methods of immunoassay: an immunoenzymetric (IEMA) or sandwich immunoassay, a competitive binding (EIA) immunoassay, and a two-step immunoenzymetric immunoassay. An antigen-antibody reaction begins by combining a patient sample, control, or calibrator with a diluent in an immunoreaction test cup from the AIA-PACK reagent series.
Reason for recall
There is a possibility that the liquid suction pump on some AIA-2000 analyzers may not perform as intended and cause an insufficient volume of wash solution to be removed during the washing step. Incomplete washing of the sample may result in falsely elevated test results for the sandwich assays and falsely decreased test results for the competitive binding assays. Insufficient washing is detectable through review of the calibration data and QC trending. For example, if incomplete washing occurs, the reported values for the zero- calibration rate will be above the acceptance range. The calibration value may shift and the instrument will not calibrate successfully. If this issue occurs, there may be a delay in testing and reporting patient test results. There have been no user or patient injuries reported related to this issue.