Cobas b 123 POC system The cobas b 123 POC system is a fully… — Class II medical device recall Z-1077-2017
Terminated recall by Roche Diagnostics Operations, Inc., reported 2017-02-01, distributed nationwide. under specific settings, an issue may occur during simultaneous Sensor Cartridge and Fluid Pack change on the
| Recall number | Z-1077-2017 |
|---|---|
| Product type | Medical device |
| Classification | Class II |
| Status | Terminated |
| Voluntary or mandated | Voluntary |
| Recalling firm | Roche Diagnostics Operations, Inc., Indianapolis, IN, United States |
| Recall initiated | 2015-09-03 |
| Classified | 2017-01-23 |
| Reported by FDA | 2017-02-01 |
| Terminated | 2017-06-05 |
| Distributed | Nationwide (US) |
| Quantity | 30 |
| Reason classes | software |
| Serial numbers | 11074, 1253, 1349, 1374, 1749, 1850, 1860, 1941, 2006, 2128, 2147, 2274, 2301, 2302, 2304, 2309, 2328, 2337, 2338, 2339, 2344, 2350, 2389, 2400, 2418 and 5 more |
Product
Cobas b 123 POC system The cobas b 123 POC system is a fully automated POC system for whole blood in vitro measurement of pH, blood gases (B3G), electrolytes Nat, K+, iCaWt (ISE), hematocrit (THct), metabolites (Glu, Lac), total hemoglobin (tHb), hemoglobin derivatives (O2Hb, HHb, COT~b, MetHb), and oxygen saturation (SO2). In addition, the cobas b 123 POC system calculates derived parameters. It is dedicated for use in a Point-of-Care environment and laboratory. The integrated AutoQC module and the oximeter module are available as an option
Reason for recall
under specific settings, an issue may occur during simultaneous Sensor Cartridge and Fluid Pack change on the cobas b 123 <2> POC system and cobas b 123 <4> POC system. The issue occurs when the software function [AutoQC as follow-up] is configured to run all three levels of AutoQC only after a Fluid Pack change, but not after a Sensor Cartridge change. When both are changed simultaneously, starting with the Sensor Cartridge and followed by the Fluid Pack, the analyzer carries out only the follow-up actions associated with the Sensor Cartridge change after completing the change workflow. As a result, no follow-up AutoQC is performed and the three expected AutoQC measurements for the Fluid Pack change are not carried out. Without running quality control, there is a remote possibility that system issues would not be detected and wrong results would not be excluded on all parameters: pH, PO2, PCO2, Na+, K+, Ca++, Cl-, Glu, Lac, Hct, SO2, O2Hb, COHb, MetHb, HHb, and Bili.