Data Foundry

Medical device recalls 2012

Sleek OTW***REF 426-1201X***Inflated Balloon Dia/mm***1 — Class II medical device recall Z-2441-2012

Terminated recall by Cordis Corporation, reported 2012-10-03. On 1/20/2011 Cordis Corporation , Miami Lakes, FL initiated a recall of their Sleek OTW PTA Dilatation Cathete

Recall numberZ-2441-2012
Product typeMedical device
ClassificationClass II
StatusTerminated
Voluntary or mandatedVoluntary
Recalling firmCordis Corporation, Miami Lakes, FL, United States
Recall initiated2011-01-31
Classified2012-09-21
Reported by FDA2012-10-03
Terminated2013-11-26
Countries outside the USDE
Quantity5 units
Reason classeslabeling
Lot numbers50027149

Product

Sleek OTW***REF 426-1201X***Inflated Balloon Dia/mm***1.25***Inflated Balloon Length/mm***15***Usable Catheter Length/cm***150*** Lot 50027149***2013-09***Cordis*** Sleek***OTW***REF Cat. No. 426-1201X***PTA Dilatation Catheter***Cordis***Johnson Johnson Company***LOT Lot No. 50027149***Use by 2013-09***Sterile***EO***Method of Sterilization: ETO***ClearStream***Clearstream Technologies, Ltd.***Moyne Upper, Enniscorthy Co Wexford, Ireland***Phone: +353-53-92-37111***Fax: +353-53-92-37-100***Made in Ireland***Distributed by: Cordis Cashel***Cahir Road, Cashel, Co. Tipperary, Ireland***Tel: +353--(0)62-70000. The SLEEK OTW Percutaneous Transluminal Angioplasty (PTA) Peripheral Catheter Family is a non-reusable semi-compliant coaxial design catheter with a balloon mounted on its distal tip. The hub/"Y" connector consists of a through lumen, allowing the catheter to track over a guidewire, and a balloon port, used to inflate the balloon. The catheter shaft is small beneath the balloon achieve low profile. The distal tip is further tapered to accept the appropriate guidewire. Platinum iridium bands serve to locate the balloon under fluoroscopy. A 0.014" (0.356 mm) guidewire is recommended for use with the SLEEK OTW Catheter.

Reason for recall

On 1/20/2011 Cordis Corporation , Miami Lakes, FL initiated a recall of their Sleek OTW PTA Dilatation Catheter Model #4261201X Lot #50027149 and Model #4261501X Lot #50026688. Product is incorrectly labeled.