DURACON XL ANGLED TIB INS 11/14MM C-M064-1-300 SELF-PRESSURIZING… — Class II medical device recall Z-3200-2026
Ongoing recall by Howmedica Osteonics Corp., reported 2026-09-23, distributed nationwide. Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in
| Recall number | Z-3200-2026 |
|---|---|
| Product type | Medical device |
| Classification | Class II |
| Status | Ongoing |
| Voluntary or mandated | Voluntary |
| Recalling firm | Howmedica Osteonics Corp., Mahwah, NJ, United States |
| Recall initiated | 2026-07-30 |
| Classified | 2026-09-16 |
| Reported by FDA | 2026-09-23 |
| Distributed | Nationwide (US) |
| Countries outside the US | CA, ZA |
| Quantity | 12,156 us |
| Reason classes | device malfunction |
| UPC / GTIN / UDI-DI | 07613327138153, 07613327138177, 07613327138191, 07613327138207, 07613327138214, 07613327138238, 07613327138269, 07613327138283 |
| Lot numbers | 1NMMPE, 1NNMPE, 5361-6105, 5361-6107, 5361-6109, 5361-6111, 5361-6205, 5361-6207, 5361-6209, 5361-6211, AF2K03Z, AF2S09U, AF2S09Z, AF2S10B, AF2S10F, AF2S10G, AF3E00, AF3E00B, AF3E00F, AF3E00G, AF3E00Q, AF3E00S, AF3E02I, AF3E02S, AF3E02Z, AFZS09F, AFZS09G, AFZS09S, AFZS10S, AFZS10U, AFZT00U, AFZT00Z, C-M062-6-800, C-M062-7-500, C-M063-2-600, C-M063-5-000, P1H39Q, P1H41, P2N04B, P2N08 and 82 more |
Product
DURACON XL ANGLED TIB INS 11/14MM C-M064-1-300 SELF-PRESSURIZING GLENOID SIZE 8 C-M062-6-800 C-M062-7-500 C-M063-2-600 SELF-PRESSURIZING GLENOID SIZE 9 C-M063-5-000 SHOULDER - GLENOID #11 5361-6111 SHOULDER - GLENOID #5 5361-6105 SHOULDER - GLENOID #7 5361-6107 SHOULDER - GLENOID #9 5361-6109 SHOULDER - KEELED GLENOID #11 5361-6211 SHOULDER - KEELED GLENOID #5 5361-6205 SHOULDER - KEELED GLENOID #7 5361-6207 SHOULDER - KEELED GLENOID #9 5361-6209 Orthopaedic implant components manufactured from UHMWPE (polyethylene)
Reason for recall
Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to hazards such as excessive wear debris, material fragments, fractured device, or disassociated device. Potential harms include revision surgery, pain, and inflammation.